})(window,document,'script','dataLayer','GTM-5JCZWWR4');
LED Driver OTM-SS18-CB12 OTM-SS18-CB24 | 18W 12V 24V led light driver | justleddriver.com
gtag('config', 'AW-16974571023');
×
By using this website, you agree to our Privacy Policy Which provides more information about our privacy practices, and our Terms of use. For more information see our Cookie Policy
Suitable for dry or damp location use Protection:Short Circuit/Over Loading/Over Current/ Over Temperature 3 years warranty With 6-10 JST ports
Model No.
Power
Output Voltage
Output Current
Weight
Size(L*W*Hmm)
Packing
OTM-SS18-CB
18W
12V
24V
1.5A
0.75A
91g
118*52*18
40*30*20CM/CTN
OTM-SS24-CB
24W
12V
24V
2.00A
1.00A
91g
118*52*18
40*30*20CM/CTN
OTM-SS30-CB
30w
12V
24V
2.50A
1.25A
91g
118*52*18
40*30*20CM/CTN
OTM-SS36-CB
36w
12V
24V
3.00A
1.50A
91g
138*55*18
40*30*20CM/CTN
OTM-SS50-CB
50W
12V
24V
4.17A
2.08A
91g
138*55*18
40*30*20CM/CTN
OTM-SS60-CB
60W
12V
24V
5.00A
2.50A
117g
168*60*20
40*30*20CM/CTN
OTM-SS75-CB
75W
12V
24V
6.25A
3.13A
207g
198*60*20
40*30*20CM/CTN
OTM-SS80-CB
80W
12V
24V
6.66A
23.33A
207g
198*60*20
40*30*20CM/CTN
OTM-SS100-CB
100W
12V
24V
8.30A
4.16A
207g
198*60*20
40*30*20CM/CTN
Specifications
Protection
Short Circuit
Hiccup mode, recover automatically after fault condition is removed
Over Current
≤1.2*I out
Over Loading
≤120%
Over temperature
100°C士10°C,Shut down o/p voltage,recover automatically after temperature goes down.
Environment
Working TEMP.
-40~+60°C
Working Humidity
-40~+80°C,10~95%RH
Storage TEMP. Humidity
-40~+70*C,5~95%RH
TEMP .cofficient
士0.039%/9C (0~50°C)
Vibration
10~500Hz,2G 12min./1 cycle,period for 72min. each along X,Y,Z axes
Safety& EMC
Safety standards
EN61347-1 EN61347-2-13
Withstand voltage
I/P-O/P:3KVAC IP. FG:1.88KVAC O/P-FG:0.5KVAC
Isolation resistance
I/P-0/P /P-FG O/P-FG:100MΩ/500VDC/25*C/70%RH
EMC EMISSION
EN55022, EN55015 Class B
Notes
1. All parameters if NOT specially mentioned are measured at 120VAC input , rated load and 25°C of ambient temperature.
2. To extend the driver's using life ,please reduce the loading at lower input voltage
Package
Dimensions
Driver Connecting Diagram
Warning
※Prevent to reverse polarity; ※Risk of Electric Shock. When used outdoors, install only on a circuit protected by a Class A GFCI; ※Risk
of Fire. Istallation involves special wiring methods to run wiring
through a building structure. Consult a qualified electrician; ※Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface.